Filter Results By:

Products

Applications

Manufacturers

Showing results: 1981 - 1995 of 2617 items found.

  • Ground-Fault Location Products for Ungrounded Systems

    Bender Inc.

    When combined with Bender's ground-fault detectors and current transformers, EDS series modules provide fast, automatic ground-fault location in ungrounded systems. Fault location takes place while the system remains online without the need to open branch circuit breakers or disconnect equipment. Bender's fault location system works on both AC and DC systems, as well as systems with variable frequency drives. A standalone, portable fault location system is also available.

  • High Impedance Active Probes

    12C - Picoprobe

    A high speed, high input impedance active probe for measuring the internal node voltage of integrated circuits. The input is 1 megohm shunted by 0.1 pf and the rise/fall times are 0.8 ns. This instrument has full dc capability and can be used with any oscilloscope. The Model 12C was specially designed so that when used in conjunction with a high input impedance oscilloscope, signal attenuation is 10:1 and with a 50 Ohm input, signal attenuation is 20:1.

  • NI-9260, 51.2 kS/s/ch Simultaneous, 3 Vrms, 2-Channel C Series Voltage Output Module

    783466-01 - NI

    51.2 kS/s/ch Simultaneous, 3 Vrms, 2-Channel C Series Voltage Output Module - The NI‑9260 is an instrument-grade dynamic signal generator for testing the audio components and capabilities of consumer electronic devices and providing excitation in structural test applications. Unlike sound card-based solutions, the NI‑9260 can be deployed quickly and recalibrated to guarantee long-term measurement repeatability and decreased test time. It also features ±30 V overvoltage protection and short circuit protection.

  • NI-9260, 51.2 kS/s/ch Simultaneous, 3 Vrms, 2-Channel C Series Voltage Output Module

    783467-01 - NI

    51.2 kS/s/ch Simultaneous, 3 Vrms, 2-Channel C Series Voltage Output Module - The NI‑9260 is an instrument-grade dynamic signal generator for testing the audio components and capabilities of consumer electronic devices and providing excitation in structural test applications. Unlike sound card-based solutions, the NI‑9260 can be deployed quickly and recalibrated to guarantee long-term measurement repeatability and decreased test time. It also features ±30 V overvoltage protection and short circuit protection.

  • Transformer Testing

    Technology Products

    The ART-3D series of Automatic Ratio Testers are precision instruments, designed to measure the turn ratios, phase displacements, excitation currents of single phase and three phase power, distribution and instrument transformers in conformity to the IEEE C57.12.90 & IEC 60076. Now featuring an enhanced test lead design, the ART-3D is the perfect instrument for real-life field usage. ART-3D series also has Anti Induction circuit which makes it suitable for system voltages upto 765KV.

  • Insulation & Multifunction Tester (LCD Display)

    4101 IN - Standard Electric Works Co., Ltd

    ● Measures Insulation Resistance, voltage (AC-DC) measurements.● Automatic hold facility.● Continuity test with a short circuit current of minimum 200mA.● Energy conservation is feature.● EnerSave™ limits the test duration to about 10 Seconds to save energy.● No moving parts. All calibration are saved internally in a non volatile memory.● Easy calibration at any facility around the world.● Low cost maintenance, calibration, and ownership.● Complies to all the latest regulations, including UK.

  • Noise Sensor

    CRY2100 Series - CRYSOUND

    CRY2100 series noise sensor has tiny structure and is equipped with precision measurement microphone which guarantees a good temperature and humidity characteristics. Noise sensor which integrates with signal conditioning circuit and DSP chip can provide dynamic range up to 110dB, and measure the ambient noises as low as 25 dBA. Noise sensor also has an RS-485 bus interface which can support Modbus RTU protocol, and a 4-20mA analog signal output port.

  • High-Frequency Probe, 300 kHz to 3 GHz

    85024A - Keysight Technologies

    85024A high-frequency probe makes it easy to perform in-circuit measurements. An input capacitance of only 0.7 pF shunted by 1 megohm of resistance permits high frequency probing without adversely loading the circuit under test. Excellent frequency response and unity gain guarantee high accuracy in swept measurements with this probe. High probe sensitivity and low distortion levels allow measurements to be made while taking advantage of the full dynamic range of RF analyzers.

  • Low Resistance Ohmmeters

    Megger Group Ltd.

    Some times know as Ducter testers, these are highly accurate, easy to operate instruments that measure resistance with resolution as fine as 0.1 micro-ohm. Digital micro-ohmeters and DLROs measure contact resistance of switch and circuit breakers, aircraft frame bonds, and rail and pipeline bonds just to name a few of the applications. Megger has models available for testing using test currents from 0.5 mA to 200 amps covering a multitude of applications that require precise low-resistance measurements.

  • Digital Signal Generator

    MCH Instruments Co.,Ltd.

    Digital Signal Generator*signal frequency:0.1Hz~2MHz, continuously variableave from: square, sine*output attenuator: 0dB,, 20dB, 40dB, 60dB*output level: 20Vp-p in open circuit, not less than 10Vp-p with 50Ω load*rising and falling edge of square not more than 35ns,*sine distortion less than 1%, amplitude –frequency characteristic : ±0.5dB within 100KHz, ±1dB above 1MHz*frequency meter: 10Hz~30MHz*power supply : AC 220V(110V optional)

  • Digital to Synchro and Digital to Resolver Converters

    Computer Conversions Corporation

    1.2VA, 1.5VA, 4.5VA and 5VA Models60 or 400, & 60 and 400 Hz. Models to 22 KHz.Trouble Free Isolated Reference Inputs & Signal OutputsUltra High Efficiency, Low DistortionSelf Powered off the AC Reference Input (DSP Series)Internal Cool AC-Pulsating Supplies (DSP Series)Very Low Loss & Heat DissipationFULLY INTEGRATED, NO EXTERNAL COMPONENTS REQUIREDVery High Resistance to Shock and VibrationHigh Reliability Throughout ImplementationIsolated, Transient, Therrnally & Short Circuit Protected Outputs

  • Door Contact Sensor

    ENVIROMUX-M-DCS - Network Technologies Inc

    Monitors access with a magnetic bridge sensor, which responds to any magnetic material (no special inserts necessary). Can also be used for monitoring side wall and covers. Includes mounting hardware. For normally closed circuit connection. 2-wire interface. Screw terminal. Maximum cable length: 1,000 ft. Wide actuating gap, approximately 1". Dimensions WxDxH (in): 0.5x0.5x2 (Switch), 0.5x0.5x2 (Magnet). Operating temperature: 32 to 158°F (0 to 70°C). Regulatory approvals: RoHS.

  • Electromagnetic Simulation Software

    Wave3D CMD - CEMWorks Inc.

    Wave3D CMD 'command-line' controlled suite of tools is designed for large-scale parametric modeling of electromagnetic phenomena using High-Performance Computing (HPC) facilities and Cloud computers. The package utilizes the same computational engine based on MLFMA aided Moment Method solution of the Surface-Volume Integral Equation as the Wave3D CAD package. Method of Moment analysis with multilayered media Green's function enables efficient analysis of wide range of 3D planar applications such microstip antennas, microwave circuits, and interconnects.

  • Enhanced 16 Discrete/Switch I/O Channels (±80 V, 625 mA/Ch.)

    DT5 - North Atlantic Industries

    The DT5 module (the enhanced version) features 16 independent, isolated, programmable channels that can be used for input voltage measurements (±80 V), or as a bi-directional current switch (up to 500 mA per channel). When programmed as a switch with the switch closed, both the current through the switch and the voltage across the switch can be monitored. These modules include diode clamping on each channel. Clamping is useful for inductive loads, such as relays and short circuit protection. Additional features of the DT5 (Enhanced Version) are listed below.

  • E & W-Band PIN Diode Waveguide Switches

    Fairview Microwave Inc.

    Fairview Microwave’s single-pole single-throw (SPST) and double-pole double-throw (DPDT) PIN diode waveguide switches feature fully integrated WR-10 and WR-12 waveguide ports and cover popular E-band (60 to 90 GHz) and W-band (75 to 110 GHz) frequencies. Switch circuits integrate low loss Fin-line assemblies with high performance GaAs beam-lead diodes that results in 4 dB insertion loss, greater than 25 dB of Isolation and fast switching speed < 300 nsec.

Get Help